RNA analysis#

Bioanalyzer
  1. To prepare samples, combine 1µL DNA sample to 9µL water in LoBind tubes

  2. Log into the PAN website

    ​ a. RNA-DNA QC → Place Order

    ​ b. Sample Type: cDNA

    ​ c. Assay Type: HS DNA

    ​ d. Sample Source: in vitro

    ​ e. Type in sample name and concentration

  3. Sample name will be generated from PAN website

    ​ a. Label the tubes using the given sample name and your initials

  4. Print out order form and bring samples to drop off in the PAN refrigerator